CLI commands
snmp-server readwrite
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
snmp-server readwrite <community>
Sets the read-write community string.
no snmp-server readwrite
Deletes the read-write community string.
snmp-server trap
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
snmp-server trap
Enables support for SNMP traps.
no snmp-server trap
Disables support for SNMP traps.
snmp-server trap community
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
snmp-server trap community <str>
Sets the password required by the remote host that will receive the trap.
no snmp-server trap community
Deletes the password required by the remote host that will receive the trap.
snmp-server trap destination
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
snmp-server trap destination <host> <[port number]>
Add a new trap destination.
no snmp-server trap destination <host> [<port>]
Deletes the specified trap destination.
Parameters
<host> Sets the IP address or domain name of the host that the service controller
will send traps to.
<[port number]> SNMP port number. Range 1 - 65535. By default port 162 is used
snmp-server trap heartbeat
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
snmp-server trap heartbeat
Enables sending of heartbeat traps at regular intervals.
no snmp-server trap heartbeat
Disables sending of heartbeat traps at regular intervals.