Go to Hardware MSA Enclosure Hard Disk to get the details for the device. You can
use the Beacon LED On button on this page to turn the LED on the front of the disk on, which
makes it easier to identify and replace.
NOTE: If the disk is in the server node, its details are on one of the Physical Disk pages in
Hardware Couplet <Node> <Node> Disk Controller. There are no buttons on this
page.
Possible RAID states reported on the Hardware Problem Report
CRIT: The raid set is online, however some disks are down and the vdisk is not fault-tolerant
FTDN: The raid set is online and fault-tolerant, however some of the disks are down
FTOL: The raid set is online and fault tolerant
OFFL: The raid set is offline because it using offline initialization, or because disks are down and
data may be lost
QTCR: The raid set is in a critical state and has been quarantined because some disks are missing
QTOF: The raid set is offline and has been quarantined because some disks are missing
UNKN: The raid set is shutdown (stopped)
UP: The raid set is online and does not have fault-tolerant attributes
134 Troubleshooting

Table of Contents

Other manuals for HP StoreOnce B6000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StoreOnce B6000 Series and is the answer not in the manual?

HP StoreOnce B6000 Series Specifications

General IconGeneral
BrandHP
ModelStoreOnce B6000 Series
CategoryStorage
LanguageEnglish

Related product manuals