EasyManuals Logo

HPE FlexFabric 5700 Series User Manual

HPE FlexFabric 5700 Series
314 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #273 background imageLoading...
Page #273 background image
264
Capture filter operators
Capture filters support logical operators (Table 33), arithmetic operators (Table 34), and relational
operators (Table 35). Logi
cal operators can use both alphanumeric and nonalphanumeric symbols.
The arithmetic and relational operators can use only nonalphanumeric symbols.
Logical operators are left associative. They group from left to right. The not operator has the highest
priority. The and and or operators have the same priority.
Table 33 Logical operators for capture filters
Nonalphanumer
ic symbol
Alphanumeric
symbol
Description
! not
Reverses the result of a condition.
Use this operator to capture traffic that matches the opposite
value of a condition.
For example, to capture non-HTTP traffic, use
not port 80
.
&& and
Joins two conditions.
Use this operator to capture traffic that matches both conditions.
For example, to capture non-HTTP traffic that is sent to or from
1.1.1.1, use
host 1.1.1.1 and not port 80
.
|| or
Joins two conditions.
Use this operator to capture traffic that matches either of the
conditions.
For example, to capture traffic that is sent to or from 1.1.1.1 or
2.2.2.2, use
host 1.1.1.1 or host 2.2.2.2
.
Table 34 Arithmetic operators for capture filters
Nonalphanumeric
symbol
Description
+ Adds two values.
- Subtracts one value from another.
* Multiplies one value by another.
/ Divides one value by another.
&
Returns the result of the bitwise AND operation on two integral values in binary
form.
| Returns the result of the bitwise OR operation on two integral values in binary form.
<<
Performs the bitwise left shift operation on the operand to the left of the operator.
The right-hand operand specifies the number of bits to shift.
>>
Performs the bitwise right shift operation on the operand to the left of the operator.
The right-hand operand specifies the number of bits to shift.
[ ]
Specifies a byte offset relative to a protocol layer. This offset indicates the byte
where the matching begins.
You must enclose the offset value in the brackets and specify a protocol qualifier.
For example,
ip[6]
matches the seventh byte of payload in IPv4 packets (the byte
that is six bytes away from the beginning of the IPv4 payload).

Table of Contents

Other manuals for HPE FlexFabric 5700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexFabric 5700 Series and is the answer not in the manual?

HPE FlexFabric 5700 Series Specifications

General IconGeneral
Product LineHPE FlexFabric
Model5700 Series
Power SupplyRedundant power supply options
Layer SupportLayer 2/3
ManagementHPE Intelligent Management Center (IMC), CLI, SNMP
Routing ProtocolRIP, OSPF, BGP, IS-IS
FeaturesVirtualization
Compliant StandardsIEEE 802.1D, IEEE 802.1Q, IEEE 802.1w, IEEE 802.1s, IEEE 802.3ad, IEEE 802.3ae
Operating Temperature32°F to 113°F (0°C to 45°C)
Operating Humidity10% to 90% (noncondensing)
LatencyLess than 1 µs

Related product manuals