2. Remove the dust plug or protective cover from the transceiver.
3. Connect a compatible LAN segment cable to the transceiver.
4. Make sure that the NIC link LED on the port is solid green.
For more information on the port LED behavior, see the documentation that ships with the transceiver.
5. If needed, see the transceiver documentation for the model-specific fastening mechanism applicable to the transceiver.
ResultsResults
The installation is complete.
Fan optionsFan options
The server supports redundant fan option (P47219-B21) for bay 1 and second processor fan options (P47902-B21) for bays 5–8. Both
options use the same fan.
These two options are required for specific hardware component.
SubtopicsSubtopics
Fan populationFan population
Fan redundancy supportFan redundancy support
Fan mode behaviorFan mode behavior
Installing a fanInstalling a fan
Fan populationFan population
In a single-processor, nonredundant configuration, fans 2–4 are preinstalled in the fan cage while fan blank is preinstalled in bay 1.
Dual-processor, nonredundant configuration requires a fan option in bay 1.
To enable the single- or dual-processor redundant fan mode, install fan options in bay 1 and bays 5–8.
To maintain proper system cooling, install the correct fan required for specific hardware components:
Hardware componentHardware component Bay 1Bay 1 Bays 2–4Bays 2–4 Bays 5–8Bays 5–8 Fan redundancyFan redundancy
HPE NS204i Boot Device Fan Fan Not supported
HPE ProLiant ML350 Gen11 Server User Guide 100