14. Connect all peripheral cables to the server.
15. Connect each power cord to the server.
16. Connect each power cord to the power source.
17. Power up the server.
ResultsResults
The installation is complete.
Storage controller optionsStorage controller options
The server supports the following storage controllers:
Intel Virtual RAID on CPU (Intel VROC) —Provides enterprise-level hybrid RAID support for direct attached SATA and NVMe SSDs.
HPE MR type-o and type-p Gen11 controllers
HPE SR type-p Gen11 controllers
For more information on drive array and storage controller configuration, see Configuring storage controllers.
SubtopicsSubtopics
Preparing the server for storage controller installationPreparing the server for storage controller installation
Installing a type-p storage controllerInstalling a type-p storage controller
Installing a type-o storage controllerInstalling a type-o storage controller
Preparing the server for storage controller installationPreparing the server for storage controller installation
PrerequisitesPrerequisites
Before beginning this procedure, download the Service Pack for ProLiant (SPP) from the Hewlett Packard Enterprise website
(https://www.hpe.com/servers/spp/downloadhttps://www.hpe.com/servers/spp/download).
ProcedureProcedure
1. If the server was previously configured:
a. Back up data on the system.
b. Close all applications.
c. Ensure that users are logged off and that all tasks are completed on the server.
CAUTION:CAUTION: In systems that use external data storage, be sure that the server is the first unit to be powered down
and the last to be powered back up. Taking this precaution ensures that the system does not erroneously mark the
drives as failed when the server is powered up.
2. If the server firmware is not the latest revision, update the firmware.
3. If the new controller is the new boot device, install the controller drivers .
Installing a type-p storage controllerInstalling a type-p storage controller
PrerequisitesPrerequisites