1 Fault/Locate Solid amber Drive has failed, unsupported, or invalid.
Solid blue Drive is operating normally and being identified by a management
application.
Flashing amber/blue (1
flash per second)
Drive has failed, or a predictive failure alert is received for the drive. The
drive has also been identified by a management application.
Flashing amber (1 flash
per second)
Drive predictive failure alert is received. Replace the drive as soon as
possible.
Off Drive is operating normally and is not identified by a management
application.
2 Online/Activity Solid green Drive is online and has no activity.
Flashing green (1 flash per
second)
Drive is doing one of the following:
Rebuilding or performing a RAID
Erasing
Flashing green (4 flashes
per second)
Drive is operating normally and has activity.
Off Drive is not configured by a RAID controller or is a spare drive.
ItemItem LEDLED StatusStatus DefinitionDefinition
SetupSetup
This chapter describes general operational requirements and safety reminders, as well the initial setup procedure for the server.
SubtopicsSubtopics
Operational requirementsOperational requirements
Rack warnings and cautionsRack warnings and cautions
Server warnings and cautionsServer warnings and cautions
Electrostatic dischargeElectrostatic discharge
Initial system installationInitial system installation
Removing the shipping bracketsRemoving the shipping brackets
Operational requirementsOperational requirements
When preparing the site and planning the installation for the HPE ProLiant ML350 Gen11 Server, be sure to observe the following
general operational requirements:
Space and airflow requirements
Temperature requirements
Power requirements
Electrical grounding requirements
For server-specific environmental requirements, see Environmental specifications.
SubtopicsSubtopics
Space and airflow requirementsSpace and airflow requirements
Temperature requirementsTemperature requirements