and Thermal Options > Thermal Configuration.
b. Select Increased CoolingIncreased Cooling.
c. Save your setting.
d. Reboot the server. A reboot is required after the setting is saved.
2. To enable the increased cooling function in the iLO web interface:
a. From the iLO web interface, select Power & Thermal > Fans.
b. Click next to the Summary category.
The Fan Settings page opens.
c. Select Increased CoolingIncreased Cooling.
d. Click OKOK.
Optical drive optionOptical drive option
Install a slim-type SATA optical drive to read/write data on optical discs.
SubtopicsSubtopics
Installing an optical driveInstalling an optical drive
Installing an optical driveInstalling an optical drive
PrerequisitesPrerequisites
Before you perform this procedure, make sure that you have the following items available:
Optical drive SATA-power cable option kit (P56688-B21)
T-15 Torx screwdriver
Phillips No. 1 screwdriver
Spudger or any small prying tool
About this taskAbout this task
Install an optical drive in the optical drive bay.
CAUTION:CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
CAUTION:CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated
with either a component or a blank.
ProcedureProcedure
1. Remove the front bezel.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.