Loading...
They must be either all hard drives or all solid-state drives.
Drives must be the same capacity to provide the greatest storage space efficiency.
Installing a hot-plug SAS, SATA, or NVMe driveInstalling a hot-plug SAS, SATA, or NVMe drive
About this taskAbout this task
CAUTION:CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
CAUTION:CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated
with either a component or a blank.
ProcedureProcedure
1. Open the front bezel:
a. Unlock the front bezel (callout 1).
b. Open the front bezel (callout 2).
2. Remove the drive blank.
Retain the blank for future use.
LFF drive blank
HPE ProLiant ML350 Gen11 Server User Guide 67