To enable the flash-backed write cache (FBWC) feature of a storage controller option, install an energy pack.
For more information on the controller caching feature, see the controller QuickSpecs on the Hewlett Packard Enterprise website
(https://www.hpe.com/info/qshttps://www.hpe.com/info/qs).
Before you perform this procedure, make sure that you have the following items available:
Compatible controller cable
T-10 Torx screwdriver
About this taskAbout this task
CAUTION:CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up .
If the server is in rack mode, remove the server from the rack .
5. Remove the access panel .
6. Do one of the following:
Remove the primary riser cage.
Remove the secondary riser cage.
7. Remove the riser slot blank.
Retain the screw. This screw will be used to secure the type-p controller.
HPE ProLiant ML350 Gen11 Server User Guide 111