96 Enable Soft Start
9.3.1 Enable Soft Start
When soft start is enabled, it is applied the next time the mold heaters are ON.
To enable soft start, do the steps that follow:
1. On the System Setup screen, touch the Heats Setup tab and then the Control Page 1
tab.
2. On the Soft Start area of the screen, touch the Soft Start Enable check box, so the check
mark shows.
9.3.2 Disable Soft Start
When soft start is disabled, it will not be applied until the next time the mold heaters are ON.
To disable soft start, do the following:
1. On the System Setup screen, touch the Heats Setup tab and then the Control Page 1
tab.
2. On the Soft Start area of the screen, touch the Soft Start Enable check box, so the check
mark does not show.
9.3.3 Adjust the Soft Start Minimum Limit
The Soft Start limit is used to calculate the window between the lowest temperature zone
and the highest temperature zone in the system. This window is used during the Soft Start
process and controls the gap between the coldest and hottest zones. Usually, a lower Soft
Start Limit value decreases the gap, which gives better thermal uniformity of the hot runner
system from a cold startup.
To adjust the Soft Start Minimum Limit, do the steps that follow:
1. On the System Setup screen, touch the Heats Setup tab and then the Control Page 1
tab.
2. On the Soft Start area of the screen, touch the Soft Start Minimum Limit field.
3. Enter the Soft Start Minimum Limit temperature value.
9.4 Alarms Screen
The Alarms screen shows the system errors that occur. Refer to Figure 9-1.
When an alarm is active, an icon in the Alarms button (at the bottom of the Altanium screen)
changes to yellow and flashes red. Touch the Alarms button to open the Alarms screen.
NOTE: For a description of the alarm conditions shown on the Event History screen and
Alarm screen, refer to Section 9.7. For a description of the abort conditions shown on
the Event History screen and Alarm screen, refer to Section 9.8.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Husky Altanium Matrix5 and is the answer not in the manual?

Husky Altanium Matrix5 Specifications

General IconGeneral
BrandHusky
ModelAltanium Matrix5
CategoryController
LanguageEnglish

Related product manuals