v 1.0 — February 2020 Altanium Matrix5
64 Setpoint Limits
7.6.1.3 Setpoint Limits
The Setpoint Limits fields are described in Table 7-7.
7.6.1.4 Manual Standby
The Manual Standby fields are described in Table 7-8.
Table 7-7 Setpoint Limits Fields
Item Description
Temperature Minimum
These values specify the range limits in which the Temperature Setpoint
field can be set.
Temperature Maximum
Power Minimum
These values specify the percentage range limits in which the Power
Setpoint field can be set.
Power Maximum
Table 7-8 Manual Standby Fields
Item Description
Temperature Setpoint The temperature to which all zones are set when the Standby button is
touched. This setting can be used to lower all zone temperatures to their
Manual Standby temperature setpoint until the timer completes or the
user touches the Standby button again. Possible values are 0 to 500 °C or
32 to 932 °F. The default value is 121 °C or 250 °F.
Temperature Minimum
These values specify the range limits in which the Standby temperature
can be set.
Temperature Maximum
Power Setpoint The power output to which all zones are set when the Standby button is
touched. This setting can be used to lower all zone power setpoints to
their manual standby power setpoint until the timer completes or the
user touches the Standby button again. Possible values are 0% – 100%.
The default value is 10%.
Power Minimum
These values specify the percentage range limits in which the Standby
power can be set.
Power Maximum

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Husky Altanium Matrix5 and is the answer not in the manual?

Husky Altanium Matrix5 Specifications

General IconGeneral
BrandHusky
ModelAltanium Matrix5
CategoryController
LanguageEnglish

Related product manuals