Input/Output Connector Pin-Out Description 185
User Guide v 1.0 — February 2020 System Options
13.3 Input/Output Connector Pin-Out Description
The sub-sections that follow give the connection details for all of the optional inputs and
output signals. Inputs are active High (12 VDC with a maximum current rating of 1 A). All
outputs are a dry contact relay type.
13.3.1 Input Base Connector ID
The input connector pins are identified in Table 13-7.
4 EtherCAT, if
equipped
Communication to UltraSync-E Gen2, Altanium Servo Control,
Individual Servo Vale Gate, or Valve Gate Sequencer systems.
5 Inputs, if
equipped
Configurable digital inputs.
6 Outputs, if
equipped
Configurable digital outputs.
7 Output COMM CANBus communication to Altanium mainframe.
8 USB Ports Touchscreen signal to secondary touch monitor.
NOTE: Only used if controller was ordered with this option.
9 Touch Screen Touch screen signal to the primary touch monitor.
10 LCD 12 VDC Out Power to the primary touch monitor.
11 Display Port Video signal to secondary touch monitor.
NOTE: Only used if the controller was ordered with this option.
12 Part Count, if
equipped
Part count option signals.
13 Remote Load, if
equipped
Remote load option signals.
Table 13-6 Matrix5 Connector Identification (Continued)
Item Cable Connection Description
Table 13-7 Input Base Connector Pins
Connector/Pin Field Cable Wire Color Signal Function
Input / A WHT Remote standby
Input / B WHT/BLK Remote boost
Input / C BLK Remote start
Input / D BLK/WHT Cooling lines not enabled