v 1.0 — February 2020 Altanium Matrix5
172 Data Collection Stop Conditions
Yes Yes Yes Yes If pair of digital inputs (start and end):
• End digital input does not go high before the
cycle time limit has expired
• Heats are turned off or not At Temperature
• UltraSync-E is disengaged or disabled
• Mold Servo Controller is disengaged or
disabled
System changes to timed data collection
If one digital input to start and timer to end data
acquisition:
• Start digital input is not high again before the
cycle time limit has expired
• Heats are turned off or not At Temperature
• UltraSync-E is disengaged or disabled
• Mold Servo Controller is disengaged or
disabled
System changes to timed data collection
If one digital input to start and end data
acquisition:
• Start digital input does not go high again
before the cycle time limit has expired
• Heats are turned off or not At Temperature
• UltraSync-E is disengaged or disabled
• Mold Servo Controller is disengaged or
disabled
System changes to timed data collection
Table 12-5 Cycle Mode - Conditions to Stop (UltraSync-E or Altanium Servo Control Installed) (Continued)
Heats Running
Condition
Enabled
UltraSync-E
Engaged
Condition
Enabled
Mold Servo
Controller
Engaged
Condition
Enabled
Cycle Mode
Conditions
Selection Shown
on Screen
Conditions to Stop