EasyManuals Logo

Hypertherm HyPerformance Plasma HPR400 User Manual

Hypertherm HyPerformance Plasma HPR400
355 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #147 background imageLoading...
Page #147 background image
OperatiOn
HPR400XD Auto Gas 806160 4-47
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Minimum
Clearance
Equivalent
Material
Thickness
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
mm mm Range (mm) mm/m mm factor % seconds
O
2
Air 15
23
84
21
2.0
3 2.5 – 8.6 6505 5.0
200
0.1
4
2.8 – 8.6
5550
5.6
0.2
5 4795
0.3
6 4035
15
8
3.0 – 8.6
3360
6.0
10 2680
12 3.3 – 8.6 2200 6.6 0.5
15
3.8 – 8.6
1665
7.6
0.7
20 1050 1.0
25 4.0 – 8.6 550 190 1.8
33
32
*
4.5 – 8.6
375 10.2 220 4.0
38 255 Edge start
Select
Gases
Set
Preflow
Set
Cutflow
Minimum
Clearance
Equivalent
Material
Thickness
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
in in Range (in) ipm in factor % seconds
O
2
Air 15
23
84
21
0.08
0.135 0.10 – 0.34 240 0.20
200
0.1
3/16
0.11 – 0.34
190
0.22
0.2
1/4 150
0.3
15
5/16
0.12 – 0.34
132
0.24
3/8 110
1/2 0.13 – 0.34 80 0.26 0.5
5/8
0.15 – 0.34
60
0.30
0.7
3/4 45 1.0
1 0.16 – 0.34 20 190 1.8
33
1-1/4*
0.18 – 0.34
15 0.40 220 4.0
1-1/2 10 Edge start
Mild steel bevel cutting
O
2
Plasma / Air Shield
130 A
Flow rates – lpm/scfh
O
2
Air
Preflow 0 / 0 64 / 135
Cutflow 33 / 70 45 / 96
220742
220637
220649220740 220179220646
Note: Bevel angle range is 0° to 45°.
220700
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps mm in mm/m ipm Volts
N
2
N
2
10 10 10 10 15 2.5 0.10 6350 250 130
Ar Air 50 10 50 10 15 3.0 0.12 2540 100 75
Marking
* Suggestions for piercing 32 mm (1-1/4 in) mild steel: 1. Turn preflow on during IHS, 2. Use ohmic contact during IHS,
3. Use pierce complete when piercing.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR400 and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR400 Specifications

General IconGeneral
Duty Cycle100% at 400 A
Cutting Capacityup to 50 mm (2 in)
Output Current30-400 A
Input Voltage200 – 480 V, 3-PH, 50/60 Hz
Gas SupplyOxygen, Air, Nitrogen