Appendix B – CnC interfACe protoCol
b-20 HPR400XD Auto Gas 806160
Error responses
If there is a problem with the serial command, the module will return an error.
Bad checksum
Return ID: 500
Description: The serial command received does not have the correct checksum.
Sample: >00091< – checksum should be 90, not 91
>50095< – bad checksum
Bad command
Return ID: 501
Description: If the module does not recognize the command ID, it will return ID 501.
Sample >999AB< – unknown ID
>50196< – bad command
Calculating checksums
Checksum is calculated on the command ID and command data only.
HELLO Command: >00090<
0 = 0x30 (ASCII value for number 0)
0 = 0x30
0 = 0x30
—————
Checksum = 0x30 + 0x30 + 0x30 = 90
READ INPUTS power supply response: >107000058<
1 = 0x31
0 = 0x30
7 = 0x37
0 = 0x30
0 = 0x30
0 = 0x30
0 = 0x30
—————
Checksum = 0x31 + 0x30 + 0x37 + 0x30 + 0x30 + 0x30 + 0x30 = 0x158
We only use the 2 least significant digits so the checksum = 58

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR400 and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR400 Specifications

General IconGeneral
Duty Cycle100% at 400 A
Cutting Capacityup to 50 mm (2 in)
Output Current30-400 A
Input Voltage200 – 480 V, 3-PH, 50/60 Hz
Gas SupplyOxygen, Air, Nitrogen