Maintenance
5-12  HPR400XD Auto Gas – 806160
Error code troubleshooting  –  error codes 030 to 042, 231 to 234
Error code 
number
Name Description Corrective action
030
Gas system 
error
Auto Gas
Only
A failure has occurred in the 
gas system.
1.  Verify that cable number 5 (power supply-to-gas console 
control cable) is not damaged and is properly connected 
to PCB3 and to the rear of the gas console.
2.  Verify that cable number 6 (power supply-to-gas console 
power cable) is not damaged and is properly connected 
inside the power supply and to the rear of the gas 
console.
3.  Verify that D1 (+5 VDC) and D2 (+3.3 VDC) are 
illuminated on PCB2 inside the gas console. These LEDs 
indicate power to PCB2.
4.  If power is present at PCB2 and PCB3 and both gas 
console cables are good, then PCB2 or PCB3 has failed. 
Use the CAN tester to verify which board needs to be 
replaced.
031
Primary
231
Secondary
Start lost
Start signal was received 
and then lost before an arc 
was established.
1.  If a mechanical relay is being used to provide the HPR 
with a start signal, this relay is either bouncing when 
activated or the contacts are faulty. Replace the relay.
2.  Inspect interface cable for damage; faulty crimps, or poor 
electrical connections.
3.  If interface cable is good and a relay is not driving the 
start input, the CNC is dropping the start signal before a 
steady state arc has been established.
032 Hold timeout
Hold signal was active for 
longer than 60 seconds.
1.  Check the interface cable for damage. The hold wires 
may be short-circuiting inside.
2.  The CNC is maintaining this input, it could be waiting for 
an IHS complete input from another torch.
3.  If CNC interface cable is good and it is a 1-torch system, 
change PCB3.
033
Precharge 
time-out
Auto Gas
Only
Selection console was not 
able to charge the lines to 
the correct value.
This is a warning for a possible gas restriction in the leads. 
Verify that there are no restrictions in the plasma and shield 
hoses, or low inlet-gas pressure.
034
Primary
234
Secondary
Lost current
Chopper 4 
HPR400XD
Only
Lost the current signal from 
Chopper 4 after transfer.
1. Verify that the consumable parts are in good condition.
2. Verify proper cut-flow gas settings.
3. Verify pierce delay time.
4.  Verify arc did not lose contact with plate while cutting 
(hole cutting, scrap cutting, etc).
042
Low nitrogen
 (N
2
) gas 
pressure
Nitrogen gas pressure 
under lower limit of:
2.07 bar (30 psi) – cutting
0.34 bar (5 psi) – marking
During N
2
 purge, when 
changing between a fuel 
gas process and an oxidizer 
process.
1. Verify that the nitrogen supply is turned on and inspect 
gas supply pressure and volume of gas remaining in 
supply tanks.
2.  Verify that the gas regulator is set to 8.27 bar (120 psi). 
See Setting the supply regulators (Installation section).