Maintenance
HPR400XD Auto Gas 806160 5-33
Coolant system servicing
Draining the coolant system
2. Remove the return coolant hose (red washer on the cooler fitting) from the rear of the cooler and put it in a 20 liter
(5 gallon) container.
4. Turn OFF the pump when the coolant stops flowing.
3.
Turn ON the pump manually, using the manual pump control button on your CNC screen.
1. Turn OFF all power to the system.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR400 and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR400 Specifications

General IconGeneral
Duty Cycle100% at 400 A
Cutting Capacityup to 50 mm (2 in)
Output Current30-400 A
Input Voltage200 – 480 V, 3-PH, 50/60 Hz
Gas SupplyOxygen, Air, Nitrogen