OperatiOn
HPR400XD Auto Gas – 806160 4-49
Mild steel
O
2
Plasma / Air Shield
200 A
220761220637 220757 220353220354
Marking
Flow rates – lpm/scfh
O
2
Air
Preflow 0 / 0 128 / 270
Cutflow 39 / 82 48 / 101
220340
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps mm in mm/m ipm Volts
N
2
N
2
10 10 10 10 15 2.5 0.10 6350 250 130
Ar Air 30 10 30 10 20 3.0 0.12 2540 100 63
220352
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
mm Volts mm mm/m mm factor % seconds
O
2
Air 23 42 74 18
5 123
3.3
5700
6.6
200
0.2
6 124 5250
8 125 4355
0.3
10 126 3460
12 128 3060 0.5
15 131
4.1
2275
8.2
0.6
20 133 1575 0.8
25 143
5.1
1165
10.2
1.0
32 145 750
Edge start38 152 510
50 163 255
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
in Volts in ipm in factor % seconds
O
2
Air 23 42 74 18
3/16
124
0.13
230
0.26
200
0.2
1/4 200
5/16 125 171
0.3
3/8 126 140
1/2 128 115 0.5
5/8 131
0.16
80
0.32
0.6
3/4 133 65 0.8
1 143
0.20
45
0.40
1.0
1-1/4 145 30
Edge start1-1/2 152 20
2 163 10