OperatiOn
HPR400XD Auto Gas 806160 4-87
Aluminum
H35 Plasma / N
2
Shield
130 A
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
mm Volts mm mm/m mm Factor % Seconds
H35 N
2
19 32 75
49
8
158 5.0
1775
6.5 130 0.3
10 1615
37 12
156
4.5
1455
7.7 170
0.5
24
15 1305 0.8
20 157 940 1.3
16 25 176 540 Edge start
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
in Volts in ipm in Factor % Seconds
H35 N
2
19 32 75
49
5/16
158 0.20
70
0.26 130 0.3
3/8 65
37 1/2
156
0.18
55
0.31 170
0.5
24
5/8 50 0.8
3/4 157 40 1.3
16 1 176 20 Edge start
Marking
Flow rates – lpm/scfh
H35 N
2
Preflow 0 / 0 76 / 160
Cutflow 26 / 54 68 / 144
220198220747 220307220755 220179220197 220340
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps mm in mm/m ipm Volts
N
2
N
2
10 10 10 10 18 2.5 0.10 6350 250 130
Ar N
2
50 10 50 10 15 3.0 0.12 2540 100 75

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR400 and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR400 Specifications

General IconGeneral
Duty Cycle100% at 400 A
Cutting Capacityup to 50 mm (2 in)
Output Current30-400 A
Input Voltage200 – 480 V, 3-PH, 50/60 Hz
Gas SupplyOxygen, Air, Nitrogen