Table 13. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
80010902-0701xxxx Numeric sensor
Planar 5V going high
(upper critical) has
asserted.
Error An upper critical
sensor going high
has asserted.
(Trained technician only) Replace the
system board (see “Removing the
system board” on page 354 and
“Replacing the system board” on page
359).
80010202-0701xxxx Numeric sensor
Planar 5V going low
(lower critical) has
asserted.
Error A lower critical
sensor going low
has asserted.
(Trained technician only) Replace the
system board (see “Removing the
system board” on page 354 and
“Replacing the system board” on page
359).
80010902-0701xxxx Numeric sensor
Planar 12V going
high (upper critical)
has asserted.
Error An upper critical
sensor going high
has asserted.
1. Check power supply n LED.
2. Remove the failing power supply.
3. (Trained technician only) Replace
the system board.
(n = power supply number)
80010202-0701xxxx Numeric sensor
Planar 12V going
low (lower critical)
has asserted.
Error A lower critical
sensor going low
has asserted.
1. Check power supply n LED.
2. Remove the failing power supply.
3. Follow actions for OVER SPEC LED
in System-board LEDs.
4. (Trained technician only) Replace
the system board.
(n = power supply number)
80010002-0701xxxx Numeric sensor
Planar VBAT going
low (lower
non-critical) has
asserted.
Warning A lower critical
sensor going low
has asserted.
Replace the system battery (see
“Removing the system battery” on page
332 and “Replacing the system battery”
on page 334).
80010202-0701xxxx Numeric sensor
Planar VBAT going
low (lower critical)
has asserted.
Error A lower critical
sensor going low
has asserted.
Replace the system battery (see
“Removing the system battery” on page
332 and “Replacing the system battery”
on page 334).
806f0008-0a01xxxx
806f0008-0a02xxxx
The Power Supply
(Power Supply n)
presence has been
added to container.
(n = power supply
number)
Info Power supply n
has been added. (n
= power supply
number)
No action; information only.
806f0009-1301xxxx The Power Supply
(Power Supply n)
has been turned off.
Info This message is for
the use case when
an implementation
has detected a
Power Unit that
has been Disabled.
No action; information only.
144 System x3530 M4 Type 7160: Installation and Service Guide