Table 13. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
806f0108-0a01xxxx
806f0108-0a02xxxx
The Power Supply n
has failed. (n =
power supply
number)
Error Power supply n
has failed. (n =
power supply
number)
1. Reseat power supply n.
2. If the power-on LED is not lit and
the power-supply error LED is lit,
replace power supply n.
3. If both the power-on LED and the
power-supply error LED are not lit,
see “Power problems” on page 254
for more information.
(n = power supply number)
806f0109-1301xxxx The Power Supply n
has been Power
Cycled. (n = power
supply number)
Info This message is for
the use case when
an implementation
has detected a
Power Unit that
has been power
cycled.
No action; information only.
806f0223-2101xxxx Powering off system
[ComputerSystemElementName]
initiated by
[WatchdogElementName].
Info This message is for
the use case when
an implementation
has detected a
Poweroff by
Watchdog has
occurred.
No action; information only.
806f0308-0a01xxxx
806f0308-0a02xxxx
The Power Supply n
has lost input. (n =
power supply
number)
Info Power supply n
AC has lost. (n =
power supply
number)
1. Reconnect the power cords.
2. Check power supply n LED.
3. See “Power problems” on page 254
for more information.
(n = power supply number)
806f0608-1301xxxx [PowerSupplyElementName]
has a Configuration
Mismatch.
Error This message is for
the use case when
an implementation
has detected a
power supply with
a configuration
error.
1. Reseat the power supply, and then
restart the server.
2. Replace the power supply.
(n = power supply number)
80070208-0a01xxxx
80070208-0a02xxxx
Sensor PS n Therm
Fault has
transitioned to
critical from a less
severe state. (n =
power supply
number)
Error A sensor has
changed to Critical
state from a less
severe state.
1. Make sure that there are no
obstructions, such as bundled
cables, to the airflow from the
power-supply fan.
2. Use the IBM Power Configurator
utility to determine current system
power consumption. For more
information and to download the
utility, go to http://www-
03.ibm.com/systems/bladecenter/
resources/powerconfig.html.
3. Replace power supply n.
(n = power supply number)
Chapter 4. Troubleshooting 145