Table 13. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
80070608-0a01xxxx
80070608-0a02xxxx
Sensor PS n 12V
AUX Fault has
transitioned to
non-recoverable from
a less severe state. (n
= power supply
number)
Error A sensor has
changed to
non-recoverable
state from a less
severe state.
1. Check power supply n LED.
2. Replace power supply n.
(n = power supply number)
80070608-0a01xxxx
80070608-0a02xxxx
Sensor PS n 12V OC
Fault has
transitioned to
non-recoverable from
a less severe state. (n
= power supply
number)
Error A sensor has
changed to
non-recoverable
state from a less
severe state.
1. Use the IBM Power Configurator
utility to determine current system
power consumption. For more
information and to download the
utility, go to http://www-
03.ibm.com/systems/bladecenter/
resources/powerconfig.html.
2. Check the OVER SPEC LED in
“Light path diagnostics LEDs” on
page 109.
80070608-0a01xxxx
80070608-0a02xxxx
Sensor PS n 12V OV
Fault has
transitioned to
non-recoverable from
a less severe state. (n
= power supply
number)
Error A sensor has
changed to
non-recoverable
state from a less
severe state.
1. Check power supply n LED.
2. Remove the failing power supply.
3. (Trained technician only) Replace
the system board.
(n = power supply number)
80070608-0a01xxxx
80070608-0a02xxxx
Sensor PS n 12V UV
Fault has
transitioned to
non-recoverable from
a less severe state. (n
= power supply
number)
Error A sensor has
changed to
non-recoverable
state from a less
severe state.
1. Check power supply n LED.
2. Remove the failing power supply.
3. Follow actions for OVER SPEC LED
in System-board LEDs.
4. (Trained technician only) Replace
the system board.
(n = power supply number)
800b0008-1301xxxx Power Unit has been
fully redundant.
Info Power unit
redundancy has
been restored.
No action; information only.
800b0108-1301xxxx Power Unit
redundancy lost has
asserted.
Error Redundancy has
been lost and is
insufficient to
continue operation.
1. Check the LEDs for both power
supplies.
2. Follow the actions in “Power-supply
LEDs” on page 114.
806f0608-1301xx03 Power supply PS
Configuration error
with rating
mismatch.
Error A power supply
configuration error
(rating mismatch)
has occurred.
1. Make sure that the power supplies
installed are with the same rating or
wattage.
2. Reinstall the power supplies with
the same rating or wattage.
Microprocessor messages
146 System x3530 M4 Type 7160: Installation and Service Guide