Table 13. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
806f0107-0301xxxx
806f0107-0302xxxx
The Processor CPU n
Status has been
detected an
over-temperature
condition. (n =
microprocessor
number)
Error An over
temperature
condition has
occurred.
1. Make sure that the latest levels of
firmware and device drivers are
installed for all adapters and
standard devices, such as Ethernet,
SCSI, and SAS.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
2. Update the firmware (UEFI and
IMM) to the latest level “Updating
the firmware” on page 71).
3. Run the DSA program.
4. Reseat the adapter (see “Removing
an adapter” on page 299 and
“Replacing an adapter” on page
300).
5. Replace the adapter.
6. (Trained technician only) Replace
microprocessor n (see “Removing a
microprocessor and heat sink” on
page 347 and “Installing an
additional microprocessor and heat
sink” on page 50).
7. (Trained technician only) Replace
the system board (see “Removing
the system board” on page 354 and
“Replacing the system board” on
page 359).
(n = microprocessor number)
806f0207-0301xxxx
806f0207-0302xxxx
The Processor CPU n
Status has Failed
with BIST condition.
(n = microprocessor
number)
Error A processor failed -
BIST condition has
occurred.
1. Make sure that the fans are
operating. There are no obstructions
to the airflow (front and rear of the
server), the air baffles are in place
and correctly installed, and the
server cover is installed and
completely closed.
2. Make sure that the heat sink for
microprocessor nis installed
correctly.
3. (Trained technician only) Replace
microprocessor n (see “Removing a
microprocessor and heat sink” on
page 347 and “Replacing a
microprocessor and heat sink” on
page 349).
(n = microprocessor number)
148 System x3530 M4 Type 7160: Installation and Service Guide

Table of Contents

Other manuals for IBM System x3530 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3530 M4 and is the answer not in the manual?

IBM System x3530 M4 Specifications

General IconGeneral
BrandIBM
ModelSystem x3530 M4
CategoryServer
LanguageEnglish

Related product manuals