Table 13. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
806f0207-2584xxxx All CPUs / one of
the CPUs has failed
with FRB1/BIST
condition.
Error A Processor Failed
- FRB1/BIST
condition has been
detected.
1. Reseat the microprocessor, and then
restart the server.
2. Replace microprocessor n.
(n = microprocessor number)
806f030c-2581xxxx Scrub Failure for All
DIMMS / one of the
DIMMs on
subsystem.
Error A memory scrub
failure has been
detected.
1. Reseat the DIMM, and then restart
the server
2. Replace DIMM n.
(n = DIMM number)
806f0507-0301xxxx
806f0507-0302xxxx
806f0507-2584xxxx
The Processor CPU n
Status has a
Configuration
Mismatch. (n =
microprocessor
number)
Error A processor
configuration
mismatch has
occurred.
1. Check the CPU LED. See more
information about the CPU LED in
“Light path diagnostics LEDs” on
page 109.
2. Check for a server firmware update.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
3. Make sure that the installed
microprocessors are compatible with
each other (see “Replacing a
microprocessor and heat sink” on
page 349 for information about
microprocessor requirements).
4. (Trained technician only) Reseat
microprocessor n (see “Removing a
microprocessor and heat sink” on
page 347 and “Replacing a
microprocessor and heat sink” on
page 349).
5. (Trained technician only) Replace
microprocessor n (see “Removing a
microprocessor and heat sink” on
page 347 and “Replacing a
microprocessor and heat sink” on
page 349).
(n = microprocessor number)
Chapter 4. Troubleshooting 149