Table 13. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
806f0607-0301xxxx
806f0607-0302xxxx
806f0607-2584xxxx
An SM BIOS
Uncorrectable CPU
complex error for
Processor n has
asserted. (n =
microprocessor
number)
Error The system
management
handler has
detected an
internal
microprocessor
error.
1. Make sure that the installed
microprocessors are compatible with
each other (see “Replacing a
microprocessor and heat sink” on
page 349 for information about
microprocessor requirements).
2. Update the server firmware to the
latest level (see “Updating the
firmware” on page 71).
3. (Trained technician only) Replace
the incompatible microprocessor
(see “Removing a microprocessor
and heat sink” on page 347 and
“Replacing a microprocessor and
heat sink” on page 349).
806f0807-0301xxxx
806f0807-0302xxxx
The Processor CPU n
has been disabled. (n
= microprocessor
number)
Info A processor has
been disabled.
No action; information only.
806f0807-2584xxxx The Processor for
One of the CPUs has
been disabled.
Info A processor has
been disabled.
No action; information only.
806f0807-2584xxxx The Processor for All
CPUs has been
disabled.
Info A processor has
been disabled.
No action; information only.
806f0a07-0301xxxx
806f0a07-0302xxxx
The Processor CPU n
is operating in a
Degraded State. (n =
microprocessor
number)
Warning Throttling has
occurred for
microprocessor n.
(n =
microprocessor
number)
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow (front
and rear of the server), that the air
baffles are in place and correctly
installed, and that the server cover
is installed and completely closed.
2. Check the ambient temperature. You
must be operating within the
specifications.
3. Make sure that the heat sink for
microprocessor nis installed
correctly.
4. (Trained technician only) Replace
microprocessor n.
(n = microprocessor number)
150 System x3530 M4 Type 7160: Installation and Service Guide

Table of Contents

Other manuals for IBM System x3530 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3530 M4 and is the answer not in the manual?

IBM System x3530 M4 Specifications

General IconGeneral
BrandIBM
ModelSystem x3530 M4
CategoryServer
LanguageEnglish

Related product manuals