EasyManuals Logo

IBM x3100 M5 Type 5457 User Manual

IBM x3100 M5 Type 5457
688 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
Off: AC power is not present, or the power supply or the LED itself has
failed.
Flashing rapidly (4 times per second): The server is partially on, but not
ready to be fully turned on. The power-control button is disabled. This will
last approximately 1 to 3 minutes.
Flashing slowly (once per second): The server is ready to be turned on. You
can press the power-control button to turn on the server.
Lit: The server is turned on.
v Hard disk drive activity LEDs:
When this LED is flashing, it indicates that the associated hard disk drive is in
use.
v System-error LED:
When this yellow LED is lit, it indicates that a system error has occurred. An
LED on the system board might also be lit to help isolate the error.
See“Diagnostic tools” on page 124 for additional information.
v USB connectors:
Connect USB devices to these connectors.
v DVD eject button:
Press this button to release a DVD or CD from the DVD drive.
v DVD drive activity LED:
When this LED is lit, it indicates that the DVD drive is in use.
v Hot-swap hard disk drive activity LED (some models):
On some server models, each hot-swap drive has a hard disk drive activity LED.
When this green LED is flashing, it indicates that the drive is in use.
When the drive is removed, this LED also is visible on the SAS/SATA
backplane, next to the drive connector. The backplane is the printed circuit board
behind drive bays 4 through 7 on 3.5-inch hard disk drive models.
v Hot-swap hard disk drive status LED (some models):
On some server models, each hot-swap hard disk drive has an yellow status
LED. If this yellow status LED for a drive is lit, it indicates that the associated
hard disk drive has failed.
If an optional ServeRAID adapter is installed in the server and the LED flashes
slowly (one flash per second), the drive is being rebuilt. If the LED flashes
rapidly (three flashes per second), the adapter is identifying the drive.
When the drive is removed, this LED also is visible on the SAS/SATA
backplane, below the hot-swap hard disk drive activity LED.
22 System x3100 M5 Type 5457: Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3100 M5 Type 5457 and is the answer not in the manual?

IBM x3100 M5 Type 5457 Specifications

General IconGeneral
MemoryUp to 32 GB
Form FactorTower
ChipsetIntel C222
ProcessorIntel Xeon E3-1200 v3 series, Intel Core i3 series, Intel Pentium series
Memory TypeDDR3 ECC
Memory Slots4 DIMM slots
RAID SupportRAID 0, 1, 10
NetworkDual Gigabit Ethernet
Storage Bays4 x 3.5-inch
Operating System SupportRed Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware
Expansion Slots1 PCIe 3.0 x8

Related product manuals