806f0123-2101ffff Reboot of system [ComputerSystemElementName] initiated by [WatchdogElementName].
(IPMI Watchdog)
Explanation: This message is for the use case when an implementation has detected a Reboot by a Watchdog
occurred.
May also be shown as 806f01232101ffff or 0x806f01232101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0370
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0207-0301ffff [ProcessorElementName] has Failed with FRB1/BIST condition. (CPU 1)
Explanation: This message is for the use case when an implementation has detected a Processor Failed - FRB1/BIST
condition.
May also be shown as 806f02070301ffff or 0x806f02070301ffff
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0044
SNMP Trap ID: 40
Automatically notify Support: Yes
User response:
1. Update the latest level of system firmware and device drivers are installed for all adapters and standard devices,
such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions require specific code levels or
coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is
supported for the cluster solution before you update the code.
2. Run the DSA program.
3. Reseat the adapter.
4. Replace the adapter.
5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
6. (Trained technician only) Replace the system board.
806f0123-2101ffff 806f0207-0301ffff
Appendix A. Integrated management module II (IMM2) error messages 417