I.2018002 [I.2018002] The device found at Bus % Device % Function % could not be configured due to
resource constraints. The Vendor ID for the device is % and the Device ID is %.
Explanation: OUT_OF_RESOURCES (PCI Option ROM)
Severity: Info
User response: Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or upgraded, reseat
adapter and any attached cables.
2. Check IBM Support website for any applicable service bulletin or UEFI or adapter firmware update that applies
to this error. NOTE: It may be necessary to disable unused option ROMs from UEFI F1 setup or ASU or using
adapter manufacturer utilities so that adapter firmware can be updated.
3. Move card to a different slot. If slot not available or error re-occurs, replace adapter.
4. (Trained service technician only) If adapter was moved to a different slot and error did not re-occur, verify that
this is not a system limitation and then replace the system board. Also, if this is not the initial installation and the
error persists after adapter replacement, replace system board.
I.2018003 [I.2018003] A bad option ROM checksum was detected for the device found at Bus % Device %
Function %. The Vendor ID for the device is % and the Device ID is %.
Explanation: ROM CHECKSUM ERROR
Severity: Info
User response: Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or upgraded, reseat
adapter and any attached cables.
2. Move adapter to a different system slot, if available.
3. Check IBM Support website for any applicable service bulletin or UEFI or adapter firmware update that applies
to this error. NOTE: It may be necessary to configure slot to Gen1 or to use special utility software so that adapter
firmware can be upgraded. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings -> Devices and
I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed Selection, or the ASU Utility.
4. Replace adapter.
I.3048005 [I.3048005] UEFI has booted from the backup flash bank.
Explanation: Booting Backup UEFI Image
Severity: Info
User response: Complete the following steps:
1. Refer to service information for this product section on UEFI Recovery to return system to primary bank.
I.2018002 I.3048005
502
System x3100 M5 Type 5457: Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3100 M5 Type 5457 and is the answer not in the manual?

IBM x3100 M5 Type 5457 Specifications

General IconGeneral
BrandIBM
Modelx3100 M5 Type 5457
CategoryServer
LanguageEnglish

Related product manuals