EasyManuals Logo

IBM x3100 M5 Type 5457 User Manual

IBM x3100 M5 Type 5457
688 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
2. Turn off the server and peripheral devices, and disconnect the power cords
and all external cables.
3. Carefully turn the server on its side so that it is lying flat, with the cover
facing up.
Attention: Do not allow the server to fall over.
4. Remove the side cover (see “Removing the side cover” on page 38).
5. Remove the air baffle (see “Removing the air baffle” on page 39).
6. Locate the DIMM connectors on the system board. Determine the connectors
into which you will install the DIMMs. Install the DIMMs in the sequence
shown in the following table.
Table 6. DIMM installation sequence
Number of DIMMs Installation sequence (connectors)
First pair of DIMMs 1, 3
Second pair of DIMMs 2, 4
7. Open the retaining clips and, if necessary, remove any existing DIMM.
Attention: To avoid breaking the retaining clips or damaging the DIMM
connectors, open and close the clips gently.
8. Touch the static-protective package that contains the DIMM to any unpainted
metal surface on the outside of the server. Then, remove the DIMM from the
package.
9. Turn the DIMM so that the DIMM keys align correctly with the connector.
10. Insert the DIMM into the connector by aligning the edges of the DIMM with
the slots at the ends of the DIMM connector.
11. Firmly press the DIMM straight down into the connector by applying pressure
on both ends of the DIMM simultaneously. The retaining clips snap into the
locked position when the DIMM is firmly seated in the connector.
Note: If there is a gap between the DIMM and the retaining clips, the DIMM
has not been correctly inserted; open the retaining clips, remove the DIMM,
and then reinsert it.
12. If you have other devices to install, do so now. Otherwise, go to “Completing
the installation” on page 82.
To install a DIMM on the 5U server model with hot-swap power supplies,
complete the following steps. For 4U server models with non-hot-swap power
supplies, please see the above sub-section.
Figure 26. DIMM installation
Chapter 2. Installing optional devices 47

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3100 M5 Type 5457 and is the answer not in the manual?

IBM x3100 M5 Type 5457 Specifications

General IconGeneral
MemoryUp to 32 GB
Form FactorTower
ChipsetIntel C222
ProcessorIntel Xeon E3-1200 v3 series, Intel Core i3 series, Intel Pentium series
Memory TypeDDR3 ECC
Memory Slots4 DIMM slots
RAID SupportRAID 0, 1, 10
NetworkDual Gigabit Ethernet
Storage Bays4 x 3.5-inch
Operating System SupportRed Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware
Expansion Slots1 PCIe 3.0 x8

Related product manuals