EasyManua.ls Logo

IMO SD1 Series - Page 77

IMO SD1 Series
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SD1 Series Inverters Function Parameters
-72-
Function
code
Name Description Default Modify
P07.15
High bit of
power
consumption
Display the power used by the inverter.
The power consumption of the inverter
=P07.15×1000+P07.16
Setting range of P07.15: 0~65535kWh (*1000)
Setting range of P07.16: 0.0~999.9kWh
P07.16
Low bit of
power
consumption
P07.18
R
ated power of
the inverter
0.4~3000.0kW
P07.19
Rated voltage
of the inverter
50~1200V
P07.20
Rated current
of the inverter
0.1~6000.0A
P07.21
Factory bar
code 1
0x0000~0xFFFF
P07.22
Factory bar
code 2
0x0000~0xFFFF
P07.23
Factory bar
code 3
0x0000~0xFFFF
P07.24
Factory bar
code 4
0x0000~0xFFFF
P07.25
Factory bar
code 5
0x0000~0xFFFF
P07.26
Factory bar
code 6
0x0000~0xFFFF
P07.27
Type of
present fault
0: No fault
1: OUt1
2: OUt2
3: OUt3
4: OC1
5: OC2
6: OC3
7: OV1
8: OV2
9: OV3
10: UV
11: Motor overload (OL1)
12: Inverter overload (OL2)
13: Input side phase loss (SPI)
14: Output side phase loss (SPO)
P07.28
Type of the last
fault
P07.29
Type of the last
but one fault
P07.30
Type of the last
but two fault
P07.31
Type of the last
but three fault
P07.32
Type of the last
but four fault

Table of Contents