Appendix C
-
171
-
Function
Code
Name Setting Range Default Change
FC-17
Simple PLC retentive
selection
Unit position: Retentive at power down
0: Not retentive
1: Retentive
Tens position: Retentive at stop
0: Not retentive at stop
1: Retentive at stop
00
☆
FC-18
Running time of simple
PLC reference 0
0.0s (h) to 6553.5s (h) 0.0s (h)
☆
FC-19
Acceleration/deceleration
time of simple PLC
reference 0
0 to 3 0
☆
FC-20
Running time of simple
PLC reference 1
0.0s (h) to 6553.5s (h) 0.0s (h)
☆
FC-21
Acceleration/deceleration
time of simple PLC
reference 1
0 to 3 0
☆
FC-22
Running time of simple
PLC reference 2
0.0s (h) to 6553.5s (h) 0.0s (h)
☆
FC-23
Acceleration/deceleration
time of simple PLC
reference 2
0 to 3 0
☆
FC-24
Running time of simple
PLC reference 3
0.0s (h) to 6553.5s (h) 0.0s (h)
☆
FC-25
Acceleration/deceleration
time of simple PLC
reference 3
0 to 3 0
☆
FC-26
Running time of simple
PLC reference 4
0.0s (h) to 6553.5s (h) 0.0s (h)
☆
FC-27
Acceleration/deceleration
time of simple PLC
reference 4
0 to 3 0
☆
FC-28
Running time of simple
PLC reference 5
0.0s (h) to 6553.5s (h) 0.0s (h)
☆
FC-29
Acceleration/deceleration
time of simple PLC
reference 5
0 to 3 0
☆
FC-30
Running time of simple
PLC reference 6
0.0s (h) to 6553.5s (h) 0.0s (h)
☆
FC-31
Acceleration/deceleration
time of simple PLC
reference 6
0 to 3 0
☆
FC-32
Running time of simple
PLC reference 7
0.0s (h) to 6553.5s (h) 0.0s (h)
☆
FC-33
Acceleration/deceleration
time of simple PLC
reference 7
0 to 3 0
☆
FC-34
Running time of simple
PLC reference 8
0.0s (h) to 6553.5s (h) 0.0s (h)
☆
FC-35
Acceleration/deceleration
time of simple PLC
reference 8
0 to 3 0
☆
FC-36
Running time of simple
PLC reference 9
0.0s (h) to 6553.5s (h) 0.0s (h)
☆
FC-37
Acceleration/deceleration
time of simple PLC
reference 9
0 to 3 0
☆
FC-38
Running time of simple
PLC reference 10
0.0s (h) to 6553.5s (h) 0.0s (h)
☆