4 Panel Operation
-
55
-
4
2. Quick-view mode
To show function parameters that are dened or modied by a user, set the FP-03 value to 11.
Function
Code
Denition Default Setting Range Description
FP-03
Parameter
display property
00
Unit's digit: group is
displayed.
0: Not displayed; 1: Displayed
Determine whether
the operating panel
displays quick-view
user-dened and
quick-view user
modied function
groups.
Ten's digit: group is
displayed.
0: Not displayed; 1: Displayed
View quick-view user-dened function parameter group
Press
QUICK
to enter the mode. Then the user can view the user-dened function parameters.
The user can set the function group FE (FE-00 to FE-29) to dene often used function parameters. The user
can dene up to 30 parameters to the function group FE. The function parameters FE00 to FE-15 (16 in total)
are default and can be edited by the user. If a function code in group FE is set to F0.00, it indicates that no pa-
rameter is dened by the user. If " " is displayed after you press
QUICK
, it indicates that the user-de-
ned menu is empty.The following table lists the often used parameters in the user-dened menu.
Table 4-5 Often used parameters in the user-dened menu
Function
Code
User-dened
Function Code
Parameter Name
Function
Code
User-dened
Function Code
Parameter Name
FE-00 F0-01 Control mode FE-01 F0-02
Running command
selection
FE-02 F0-03
Main frequency reference
setting channel selection
FE-03 F0-07
Frequency source
calculation selection
FE-04 F0-08 Preset frequency FE-05 F0-17 Acceleration time
FE-06 F0-18 Deceleration time FE-07 F3-00 V/F curve setting
FE-08 F3-01 Torque boost FE-09 F4-00 DI1 function selection
FE-10 F4-01 DI2 function selection FE-11 F4-02 DI3 function selection
FE-12 F5-04 DO1 output selection FE-13 F5-07 AO1 output selection
FE-14 F6-00 Start mode FE-15 F6-10 Stop mode
View user modied function parameters
Press
QUICK
to enter the mode to view function parameters that have been modied.
In this mode, you can view modied function parameters quickly. All function parameters that have been mod-
ied by a user are listed in the modied function parameter group. The current values of these parameters are
different from the default values. The AC drive automatically generated a list of modied function parameters.

Table of Contents