4 Panel Operation
-
55
-
4
2. Quick-view mode
To show function parameters that are dened or modied by a user, set the FP-03 value to 11.
Function
Code
Denition Default Setting Range Description
FP-03
Parameter
display property
00
Unit's digit: group is
displayed.
0: Not displayed; 1: Displayed
Determine whether
the operating panel
displays quick-view
user-dened and
quick-view user
modied function
groups.
Ten's digit: group is
displayed.
0: Not displayed; 1: Displayed
■
View quick-view user-dened function parameter group
Press
to enter the mode. Then the user can view the user-dened function parameters.
The user can set the function group FE (FE-00 to FE-29) to dene often used function parameters. The user
can dene up to 30 parameters to the function group FE. The function parameters FE00 to FE-15 (16 in total)
are default and can be edited by the user. If a function code in group FE is set to F0.00, it indicates that no pa-
rameter is dened by the user. If " " is displayed after you press
, it indicates that the user-de-
ned menu is empty.The following table lists the often used parameters in the user-dened menu.
Table 4-5 Often used parameters in the user-dened menu
Function
Code
User-dened
Function Code
Parameter Name
Function
Code
User-dened
Function Code
Parameter Name
FE-00 F0-01 Control mode FE-01 F0-02
Running command
selection
FE-02 F0-03
Main frequency reference
setting channel selection
FE-03 F0-07
Frequency source
calculation selection
FE-04 F0-08 Preset frequency FE-05 F0-17 Acceleration time
FE-06 F0-18 Deceleration time FE-07 F3-00 V/F curve setting
FE-08 F3-01 Torque boost FE-09 F4-00 DI1 function selection
FE-10 F4-01 DI2 function selection FE-11 F4-02 DI3 function selection
FE-12 F5-04 DO1 output selection FE-13 F5-07 AO1 output selection
FE-14 F6-00 Start mode FE-15 F6-10 Stop mode
View user modied function parameters
Press
to enter the mode to view function parameters that have been modied.
In this mode, you can view modied function parameters quickly. All function parameters that have been mod-
ied by a user are listed in the modied function parameter group. The current values of these parameters are
different from the default values. The AC drive automatically generated a list of modied function parameters.