Chapter 11: Network settings
TruVision DVR 12HD User Manual 81
3. Enter the NTP settings:
• Interval (min): Time in minutes to synchronize with the NTP server. The value
can be between 1 and 10080 minutes. Default is 60 minutes.
• NTP Server: IP address of the NTP server.
• NTP Port: Port of the NTP server.
4. Click Apply to save the settings and click Exit to return to live view.
E-mail settings
The recorder can send email notifications of alarms or notifications through the network.
Note: Ensure that the DNS address has been set up correctly beforehand.
To configure email settings:
1. From the menu toolbar, click Network Settings > Email.
2. Enter the required settings.
Check the box if your mail server requires authentication and enter the
login user name and password.
If the mail server requires authentication, enter the login user name.
If the mail server requires authentication, enter the login password.
erver Enter the SMTP server’s IP address.
ort Enter the SMTP port. The default TCP/IP port for SMTP is 25.
Check the box to enable SSL if it is required by the SMTP server. This
feature is optional.
Enter the name of the sender of the email.
ddress Enter the sender’s email address.
eceivers Select an email recipient. Up to three receivers can be selected.
Name Enter the name of the receiver of the email.
Address Enter the email address of the receiver.
Check the Attach JPEG File box if you want to send an email with
attached alarm images.
Select an interval range in the Interval box.
The interval range represents the time range in between the alarm
images being sent. For example, if you set the interval range at two
seconds, the second alarm image will be sent two seconds after the
first alarm image
3. Click Test to the test email settings.
Note: We recommend that you test the email settings after entering values in the
email window.