11
Intermec EasyCoder 201 II – Technical Manual
MODELS, cont'd. EasyCoder 201 IISA
Feature EasyCoder 201 IISA
Print Technique Direct Thermal
Quick-Mount Printhead 6 or 8 dots/mm (153.9 or 203.2 dpi) 8 dots/mm (203.2 dpi)
Print Width (6 or 8 dots/mm resp.) Max. 85.3 mm (3.36") or 80.0 mm (3.15") max. 80.0 mm (3.15")
Media Width Max. 89.0 mm (3.50")
Print Length (6 or 8 dots/mm resp.) Max. 1650 mm (65") or 1250 mm (49") max. 1250 mm (49")
Print Speed Max. 75–125 mm/sec. (3–5"/sec.)
Fonts, expandible 4 times
5
10 Bitmapped
Print Directions for Text, Images, Lines, and Boxes 4
Bar Code Generators
5
10
Internal Paper Roll Diameter Max. 125 mm (4.9")
Keyboard, built-in 21 keys plus Print button
Display 2 lines x 16 characters LCD
Dimensions (W x D x H) 225 x 418 x 159 mm (8.86 x 16.46 x 6.26")
Weight (excl. paper, ribbon and options) 9.0 kgs (20 lbs)
Ambient Operating Temperature + 5˚C – +40˚C (+41˚F – +104˚F)
Humidity 20–80% non-condensing
Sound Emission Level < 55 dB (A)
Microprocessor 32 bit
Firmware Intermec Fingerprint 6.13
Startup program Intermec Stand-Alone Concept 2.xx
On-Board RAM Memory, standard 512 kbytes
Label End Sensor Standard
Real Time Clock (RTC) Standard
Memory Card Adapter Standard
Mains Voltage (switch change-over) 115/230 VAC (+10%/-15%), 2.6/1.3 A 60/50 Hz
Max. Power Consumption 300 W
Communication Interface, standard RS 232C/20 mA Current Loop
1
1 x Centronics Interface
1,4
Optional
1 x RS 232C + 1 x RS 232C/20 mA CL
Interface
1,4
Optional
1 x RS 232C + 1 x RS 422/RS 485
Interface
1,4
Optional
1 x RS 232C + 1 x 4 IN/OUT ports
Interface
1,4
Optional
Label Taken Sensor (LTS)
1
Optional
RS 232C Cable
2
Optional
Centronics Cable
2
Optional
External RS 232C Alphanumeric Keyboard
2
Optional
Peel-Off /Internal Rewind Device
3
Optional
Cutter Unit
1
Optional
Intermec Toolbox, PC Windows configuration support
2
Optional
Intermec LabelShop, WYSIWYG Label Software for Windows
2
Optional
1
/. Available as factory installed option or field-installable kit.
2
/. Field-installable option only.
3
/. Factory-installed option only. Must be requested at time of order.
4
/. Only one interface board can be fitted.
5
/. See Intermec Stand-Alone Concept, Operating Instructions.