Intermec EasyCoder 201 II – Technical Manual
Program Example
LABEL-TAKEN SENSOR, cont'd.
The LTS can be enabled or disabled by means of the instructions
LTS& ON and LTS& OFF respectively (introduced with Intermec
Fingerprint 6.0 and the Intermec Direct Protocol). Here is an
example on how the label-taken sensor is used to control the
printing of a ten-label batch printing job. A new copy will not be
printed until the pending label has been removed.
FONT "SW030RSN"
PRTXT "HELLO"
LTS& ON
PRINTFEED 10
In Intermec Fingerprint versions earlier than 6.0, the status of the
label-taken sensor must be polled by a PRSTAT function. The same
example as above can be run by a program like this:
10 FONT "SW030RSN.1"
20 PRTXT "HELLO"
30 GOSUB 100
40 END
100 I%=10 :REM I% sets number of copies
110 IF (PRSTAT AND 2) THEN GOTO 110
120 PRINTFEED
130 I%=I%-1
140 IF I%>0 THEN GOTO 110
150 RETURN
RUN

Table of Contents