10 Uni-3 Technical Manual
1.3.10 Save File to Flash Drive
USB specifications: 8GB or smaller, FAT32 format, USB 3.0
Use the following steps to save files to a flash drive.
1. Remove Speed Key insert page.
2. Insert a flash drive.
3. Enter
6000 then press Mode. B00 SETUP will display.
4. Enter the password 495344 then press
PLU to enter service level. B00 SETUP will display.
5. Enter
27 then press the Down Arrow, then press Enter. B27-01 USB-TO-SCALE will display.
6. Press the
Right Arrow then press Enter. B27-02-01 O/P SELECT will display.
7. Press
PLU. B27-200 SEL USB FOLDER will display.
8. Press the
Down Arrow to select an empty folder. B27-20x USB DATA 0x will display.
9. Press
Edit to name folder. InP 0001 will display.
10. Type in folder name. Press
Enter. B27-02 SCALE-TO-USB will display.
11. Press
3 then press the Down Arrow. B27-02-03 MASTER MODE will display.
12. Enter
1 for Auto or 2 for Manual send. Press Enter. B27-02-03 Master Mode (with selected load choice) will
display.
13. Press
Enter. B27-02-04 EXECUTE will display.
14. Press
Zero. 14012-0000 OUTPUT CHECK will display.
15. Press
Enter to begin sending file to USB. 14014-0000 COMPLETE will display when complete.
16. Press
Enter then press Mode three times to exit Setup Mode. KEY IN ITEM No. will display.
17. Remove the flash drive. Scale is ready to resume weighing and labeling.
1.3.11 Set Product Name Display Timer
Use the following steps to set the product name display timer.
1. Remove Speed Key insert page.
2. Enter
6000 then press Mode. B00 SETUP will display.
3. Enter the password 495344 then press
PLU to enter service level. B00 SETUP will display.
4. Enter
17 then press the Down Arrow then press Enter twice. B17-01-02 OPEN PLU will display.
5. Enter
4 then press the Down Arrow. B17-01-05 SEG PLU will display.
6. Enter
2 then press Enter three times. B17-01 CALL will display.
7. Enter
2 then press the Right Arrow, then press Enter. B17-03-01 REG TMR will display.
8. Enter
4 then press the Down Arrow. B17-03-07 SEG PLU TIMER will display.
9. Enter
3 then press Enter. B17-03-07 SEG PLU TIMER will display.
10. Press Mode three times to exit Setup Mode.
KEY IN ITEM No. will display. Scale is ready to resume
weighing and labeling.