66 Uni-3 Technical Manual
4.5 C05-Firmware Details
Displays the program number and version of the firmware in the
following format:
B****# or C****#.
Example: C1937H
B: Standard Program Code
C: Option Program Code
****: Base Program four-digit number
#: Version Mark
To avoid confusion, some letters, such as I, O and Q, are not available for the version mark.
Press Mode to exit.
4.6 C06-Memory Clear
This procedure is for clearing all programmed data and resetting
configuration to factory defaults.
Display Description Choices
C05-01 Title Software Displays the program number and version of the title software. Refer to this
program number and version when checking for updates.
--
C05-02 Main Displays the program number and version of the main software. --
C05-03 Operating System Displays the program number and version of the operating system. --
C05-04 Boot ROM Displays the program number and version of the Boot ROM. --
C05-06 Scale Driver Displays the program number and version of the A/D Driver. --
C05-07 Updater Displays the program number and version of the Updater ROM. --
Table 4-3. C05 Firmware Details Parameters
Display Description Choices
C06-01 Master Data Clear Deletes all data in the program menu and custom label formats. Press Zero twice
to clear the RAM. After clearing the memory, the result is displayed: Success [OK],
Failure [NG].
--
C06-02 System Data Initial Used to restore the default settings of the system data. All of the settings of the
Setup menu are initialized to the default settings by executing this mode. Press
Zero twice to execute. After completing the initialization, the result is displayed:
success [OK], failure [NG].
--
C06-03 Test Data Set Test Data Set creates PLUs, Store Name, Preset Keys, etc. for testing purposes.
Press Zero twice to execute.
All exisiting data is deleted when Test Data Set is performed.
--
C06-04 SRAM Size Monitors the status of the SRAM. ####: Available Memory, ****:Total Memory ####-****
C06-05 SDRAM Size Monitors the status of the SDRAM. ####: Available, ****: Total. ####-****
C06-06 Flash Displays the size of the installed program and the flash ROM. #####: Total size of
program, *****: Size of flash ROM.
#####-*****
Table 4-4. C06 Memory Clear Parameters
CO5 FIRMWARE DETAILS
&2),50:$5('(7$,/6
Note
CO6 MEMORY CLEAR
&2PHPRU\FOHDU

Table of Contents

Other manuals for ISHIDA Uni-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ISHIDA Uni-3 and is the answer not in the manual?

ISHIDA Uni-3 Specifications

General IconGeneral
BrandISHIDA
ModelUni-3
CategoryScales
LanguageEnglish

Related product manuals