Introduction 9
1.3.8 Set Label Cassette for Default Label Format
Use the following steps to set label cassette for the default label format.
1. Remove Speed Key insert page.
2. Enter
6000 then press Mode. B00 SETUP will display.
3. Enter the password 495344 then press
PLU to enter service level. B00 SETUP will display.
4. Press
11 then press the Down Arrow, then press Enter. B11-01 CASSETTE No.will display.
5. Press
4 then press the Down Arrow. B11-04 FMT No. will display.
6. Enter the desired default label format number. Press
Enter. B11-04 FMT No. with number will display.
7. Press
8 then press the Down Arrow. B11-08 PRN MODE will display.
8. Enter
0 for Manual or 1 for Auto. Press Enter twice. B11-09 LBL TYPE will display.
9. Enter
0 for Die Cut or 1 for Continuous. Press Enter.
10. Enter
17 then press the Down Arrow. B11-17 PLU NAME will display.
11. Enter
0 for Fixed or 1 for Variable. Press Enter twice. B11-18 XTRAMSG1 will display.
12. Enter
0 for Fixed or 1 for Variable. Press Enter twice. B11-19 XTRAMSG2 will display.
13. Enter
0 for Fixed or 1 for Variable. Press Enter twice.B11-20 XTRAMSG3 will display.
14. Enter
0 for Fixed or 1 for Variable. Press Enter. B11-20 XTRAMSG3 will display.
When using continuous labels, settings B11-17 through B11-20 should be set to 1 for Variable.
15. Press Mode three times Setup Mode. KEY IN ITEM No. will display. The scale is ready to resume weighing
and labeling.
1.3.9 Load File from Flash Drive
USB specfications: 8 GB or smaller, FAT32 format, USB 3.0
Use the following steps to load files from a flash drive.
1. Remove Speed Key insert page.
2. Insert a flash drive containing a DATA0x Folder.
3. Enter
6000 then press Mode. B00 SETUP will display.
4. Enter the password 495344 then press
PLU to enter service level. B00 SETUP will display.
5. Enter
27 then press the Down Arrow. B27 FILE SAVE/LOAD will display.
6. Press
Enter twice. B21-01-01 I/P SELECT will display.
7. Press
PLU. B27-100 SEL USB FOLDER will display. This may take up to 30 seconds as files are scanned.
8. Press the
Down Arrow to locate file to be loaded. B27-10x and File Name will display.
9. Press
PLU to select file. B27-01 USB-TO-SCALE will display.
10. Press the
Down Arrow twice. B27-01-03 MASTER MODE will display.
11. Press
1 for Auto or press 2 for Manual load. Press Enter. B27-01-03 MASTER MODE with selected load choice
will display.
12. Press
Enter. B27-01-04 EXECUTE will display.
13. Press
Zero. 14011-0000 INPUT CHEECK will display.
14. Press
Enter to begin loading files. 14013-0000 COMPLETE INPUT will display when complete.
15. Press
Enter then press Mode three times to exit Setup Mode. KEY IN ITEM No. will display.
16. Remove the flash drive. Scale is ready to resume weighing and labeling.