72 Uni-3 Operation Manual
5.1 P01-PLU Data
1. From the program mode main menu screen, press the down
arrow once to scroll to P01 PLU.
2. Press Enter to display PLU P01-00.
3. Enter the PLU number.
4. Press
PLU.
5. Press
Enter to confirm a new item.
6. The
Sale 1 screen displays.
7. Press
Edit.
8. Edit text. See Section 6.2 on page 85.
9. Press
Enter.
10. Press
Enter to enter the lower level menus.
Parameter Display Description Choices
P01-01
Sale1
P01-01-01 SALES Enter the mode number. Press Enter to select a desired
sales mode.
0: WEIGHT
1: FIX PRI
2: WGT F/PRI
3: FIX UPR
4: WGT (100g)
P01-01-02 M/D Mode Enter the mode number. Press Enter to select a desired
markdown mode.
0: NORMAL
1: SPECIAL
2: -¢
3: -%
4: SPEC. U/P
5. U/P -¢
6: U/P -%
P01-01-03 Open Price Enter the mode number. Press Enter to select whether or not to
allow an open price system.
0: YES
1: NO
P01-01-04 Unit Price Enter the unit or fixed price. Press Enter. --
P01-01-08 Tax Enter a numeric value. Press Enter. --
P01-01-10 Tare Weight Enter tare weight. Press Enter. --
P01-01-12 % Tare Enter the tare percentage. Press Enter. --
P01-01-13 Forced Tare Enter the mode number. Press Enter to select whether or not to
use the forced tare function.
1: YES
2: NO
P01-01-14 Lower Weight Enter the lower weight limit. Press Enter. --
P01-01-15 Upper Weight Enter the upper weight limit. Press Enter. --
P01-02
Sale2
P01-02-06 Point Flag Enter the mode number. Press Enter to select whether or not to
use the point flag.
0: OFF
1: ON
P01-02-07 Point Type Enter the mode number. Press Enter to select the desired
point type.
0: WEIGHT
1: FIXED WEIGHT
P01-02-08 Points Enter a desired number. Press Enter. --
Table 5-1. P01 PLU Data
*PLU (No. +PLU)
S3/8MQRO
< SALE 1 > (ENT}
S>6$/(@
RIB STEAK
LQSU
< SALE 1 > (ENT}
S>6$/(@
*SALES O:WEIGHT
,136$/(6