3. Place the bleeding reservoir above the liquid cooling system.
4. Add coolant to the bleeding reservoir (ensure that the coolant fills the suction hose of
the pump)
5. When the suction hose of the pump is filled, fill the reservoir with coolant
6. Follow section 4.11.2.4.4 to fully bleed the liquid system.
4.11.2.4.4 Repeat the following steps until the system is bled
1. Elevate the fuselage nose by lowering the tail (ensure the pump is the lowest
component in the liquid cooling system).
2. Turn on the pump.
3. Lightly tap the radiator to ensure all the air is removed from the radiator.
4. Turn off the pump.
5. Level out the fuselage by elevating the tail.
6. Turn on the pump for 1 min.
7. Compress and decompress the silicone pipes attached to the bleeding reservoir.
8. Elevate the tail of the fuselage (ensure that the pump is the highest component of the
water system).
9. Turn on the pump.
10. Lightly tap the radiator.