EasyManua.ls Logo

JUKI PS-700 - 3. Memory Parameter List

JUKI PS-700
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3. MEMORY PARAMETER LIST
(1) Thread breakage sensor
Code Description Unit Step Range
Factory
setting
Type
PRT Thread breakage detection 0 : OFF : Thread breakage detection-OFF
1 : ON : Thread breakage detection-ON
1 Selec-
tion
TRM Thread trimming operation at
the time of thread breakage
detection
0 : ON : Thread trimming is carried out when
thread breakage is detected
1 : OFF : Thread trimming is not carried out when
thread breakage is detected
0 Selec-
tion
(2) Origin position
Code Description Unit Step Range
Factory
setting
Type
PTR Return to origin when turning
the power ON
0 : OFF : Not return to the point of origin
1 : ON : Return to the point of origin
0 Selec-
tion
(3) Temporary stop
Code Description Unit Step Range
Factory
setting
Type
TRM Automatic thread trimming at
the time of temporary stop
0 : AUT : Automatic thread trimming is carried out
1 : OFF : Automatic thread trimming is not carried
out
0 Selec-
tion
(4) Counter
Code Description Unit Step Range
Factory
setting
Type
UCM UP counter mode 0 : OFF : UP counter is prohibited
1 : PAT : UP counter is activated according to the
sewing pattern
2 : CYC : UP counter is activated according to the
cycle
1 Selec-
tion
DCM DOWN counter mode 0 : OFF : DOWN counter is prohibited
1 : PAT : DOWN counter is activated according to
the sewing pattern
2 : CYC : DOWN counter is activated according to
the cycle
1 Selec-
tion
URV Reservation of UP counter
value when a sewing pattern
is introduced
0 : CLR : Deleted
1 : RSV : Reserved
1 Selec-
tion
DRV Reservation of DOWN counter
value when a sewing pattern
is introduced
0 : CLR : Deleted
1 : RSV : Reserved
1 Selec-
tion
POC Deletion of counter value
when re-turning the power ON
0 : CLR : Deleted
1 : RSV : Reserved
1 Selec-
tion
NUP Permission/prohibition of cor-
rection of UP counter (UP)
0 : OFF : Correction is permitted
1 : ON : Correction is prohibited
0 Selec
-
tion
NDP Permission/prohibition of cor-
rection of DOWN counter (DN)
0 : OFF : Correction is permitted
1 : ON : Correction is prohibited
0 Selec-
tion
UTO Sewing machine operation in
the case the UP counter (UP)
set value is reached
0 : OFF : Sewing machine is stopped
1 : ON : Sewing machine is not stopped
0 Selec-
tion
DTO Sewing machine operation in
the case the DOWN counter
(DN) set value is reached
0 : OFF : Sewing machine is stopped
1 : ON : Sewing machine is not stopped
0 Selec-
tion
NPC Permission / prohibition of cor-
rection of the number count
generated
0 : OFF : Correction is permitted
1 : ON : Correction is prohibited
1 Selec-
tion
– 61 –

Table of Contents

Related product manuals