3. MEMORY PARAMETER LIST
(1) Thread breakage sensor
Code Description Unit Step Range
Factory
setting
Type
PRT Thread breakage detection 0 : OFF : Thread breakage detection-OFF
1 : ON : Thread breakage detection-ON
1 Selec-
tion
TRM Thread trimming operation at
the time of thread breakage
detection
0 : ON : Thread trimming is carried out when
thread breakage is detected
1 : OFF : Thread trimming is not carried out when
thread breakage is detected
0 Selec-
tion
(2) Origin position
Code Description Unit Step Range
Factory
setting
Type
PTR Return to origin when turning
the power ON
0 : OFF : Not return to the point of origin
1 : ON : Return to the point of origin
0 Selec-
tion
(3) Temporary stop
Code Description Unit Step Range
Factory
setting
Type
TRM Automatic thread trimming at
the time of temporary stop
0 : AUT : Automatic thread trimming is carried out
1 : OFF : Automatic thread trimming is not carried
out
0 Selec-
tion
(4) Counter
Code Description Unit Step Range
Factory
setting
Type
UCM UP counter mode 0 : OFF : UP counter is prohibited
1 : PAT : UP counter is activated according to the
sewing pattern
2 : CYC : UP counter is activated according to the
cycle
1 Selec-
tion
DCM DOWN counter mode 0 : OFF : DOWN counter is prohibited
1 : PAT : DOWN counter is activated according to
the sewing pattern
2 : CYC : DOWN counter is activated according to
the cycle
1 Selec-
tion
URV Reservation of UP counter
value when a sewing pattern
is introduced
0 : CLR : Deleted
1 : RSV : Reserved
1 Selec-
tion
DRV Reservation of DOWN counter
value when a sewing pattern
is introduced
0 : CLR : Deleted
1 : RSV : Reserved
1 Selec-
tion
POC Deletion of counter value
when re-turning the power ON
0 : CLR : Deleted
1 : RSV : Reserved
1 Selec-
tion
NUP Permission/prohibition of cor-
rection of UP counter (UP)
0 : OFF : Correction is permitted
1 : ON : Correction is prohibited
0 Selec
-
tion
NDP Permission/prohibition of cor-
rection of DOWN counter (DN)
0 : OFF : Correction is permitted
1 : ON : Correction is prohibited
0 Selec-
tion
UTO Sewing machine operation in
the case the UP counter (UP)
set value is reached
0 : OFF : Sewing machine is stopped
1 : ON : Sewing machine is not stopped
0 Selec-
tion
DTO Sewing machine operation in
the case the DOWN counter
(DN) set value is reached
0 : OFF : Sewing machine is stopped
1 : ON : Sewing machine is not stopped
0 Selec-
tion
NPC Permission / prohibition of cor-
rection of the number count
generated
0 : OFF : Correction is permitted
1 : ON : Correction is prohibited
1 Selec-
tion
ā 61 ā