CHAPTER 12
Performing Initial Configuration
Configuring a QFX5110 on page 99
Configuring a QFX5110
You must perform the initial configuration of the QFX5110 through the console port using
the command-line interface (CLI).
Before you begin connecting and configuring a QFX5110, set the following parameter
values on the console server or PC:
Baud Rate—9600
Flow Control—None
Data—8
Parity—None
Stop Bits—1
DCD State—Disregard
To connect and configure the switch from the console:
1. Connect the console port to a laptop or PC using the supplied RJ-45 cable and RJ-45
to DB-9 adapter. The console (CON) port is located on the management panel of the
switch.
2. Log in as root. There is no password. If the software booted before you connected to
the console port, you might need to press the Enter key for the prompt to appear.
login: root
3. Start the CLI.
root@% cli
4. Enter configuration mode.
root> configure
99Copyright © 2017, Juniper Networks, Inc.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper QFX5110 and is the answer not in the manual?

Juniper QFX5110 Specifications

General IconGeneral
ModelQFX5110
Power SupplyDual, hot-swappable
Rack Units1U
Operating Relative Humidity5% to 90% non-condensing
Input Voltage100-240 VAC
Operating SystemJunos OS
Layer SupportLayer 2 and Layer 3
Virtual Chassis SupportYes
Ports48 x 10GbE SFP+
Jumbo Frames9216 bytes
Operating Temperature32°F to 104°F (0°C to 40°C)
Operating AltitudeUp to 3, 048 m
ManagementCLI
AC Input Frequency50/60 Hz
Storage Temperature-40°C to 70°C
MTBFConsult Juniper documentation for specific values.