CHAPTER 25
Electrical Safety Guidelines and Warnings
General Electrical Safety Guidelines and Warnings on page 181
Prevention of Electrostatic Discharge Damage on page 182
Action to Take After an Electrical Accident on page 184
AC Power Electrical Safety Guidelines on page 184
AC Power Disconnection Warning on page 185
DC Power Electrical Safety Guidelines for Switches on page 186
DC Power Disconnection Warning on page 189
DC Power Grounding Requirements and Warning on page 190
DC Power Wiring Sequence Warning on page 191
DC Power Wiring Terminations Warning on page 193
Multiple Power Supplies Disconnection Warning on page 194
TN Power Warning on page 194
General Electrical Safety Guidelines and Warnings
WARNING: Certain ports on the device are designed for use as intrabuilding
(within-the-building) interfaces only (Type 2 or Type 4 ports as described in
GR-1089-CORE) and require isolation from the exposed outside plant (OSP)
cabling. To comply with NEBS requirements and protect against lightning
surges and commercial power disturbances, the intrabuilding ports must not
be metallically connected to interfaces that connect to the OSP or its wiring.
The intrabuilding ports on the device are suitable for connection to
intrabuilding or unexposed wiring or cabling only. The addition of primary
protectors is not sufficient protection for connecting these interfaces
metallically to OSP wiring.
CAUTION: Before removing or installing components of a device, attach an
electrostatic discharge (ESD) grounding strap to an ESD point and place the
other end of the straparound your bare wrist. Failure touse an ESD grounding
strap could result in damage to the device.
181Copyright © 2017, Juniper Networks, Inc.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper QFX5110 and is the answer not in the manual?

Juniper QFX5110 Specifications

General IconGeneral
ModelQFX5110
Power SupplyDual, hot-swappable
Rack Units1U
Operating Relative Humidity5% to 90% non-condensing
Input Voltage100-240 VAC
Operating SystemJunos OS
Layer SupportLayer 2 and Layer 3
Virtual Chassis SupportYes
Ports48 x 10GbE SFP+
Jumbo Frames9216 bytes
Operating Temperature32°F to 104°F (0°C to 40°C)
Operating AltitudeUp to 3, 048 m
ManagementCLI
AC Input Frequency50/60 Hz
Storage Temperature-40°C to 70°C
MTBFConsult Juniper documentation for specific values.