replace it with an equivalent Juniper Networks optic or cable that is qualified
for the device.
Related
Documentation
QFX5110-48S Port Panel on page 9•
Cable Specifications for QSFP+ and QSFP28 Transceivers
The 40-Gigabit Ethernet QSFP+ and 100-Gigabit Ethernet QSFP28 transceivers that are
used in QFX Series and EX4600 switches use 12-ribbon multimode fiber crossover cables
with female MPO/UPC connectors. The fiber can be either OM3 or OM4. These cables
are not sold by Juniper Networks.
CAUTION: To maintain agency approvals, use only a properly constructed,
shielded cable.
TIP: Ensure that you order cables with the correct polarity. Vendors refer to
these crossover cables as key up to key up, latch up to latch up, Type B, or
Method B. If you are using patch panels between two QSFP+ or QSFP28
transceivers, ensure that the proper polarity is maintained through the cable
plant.
Table 27 on page 62 describes the signals on each fiber. Table 28 on page 63 shows the
pin-to-pin connections for proper polarity.
Table 27: QSFP+ and QSFP28 Optical Module Receptacle Pinouts
SignalFiber
Tx0 (Transmit)1
Tx1 (Transmit)2
Tx2 (Transmit)3
Tx3 (Transmit)4
Unused5
Unused6
Unused7
Unused8