Understanding Alarms on page 145
Chassis Alarm Messages on QFX5100, QFX5110, and QFX5200 Switches
Chassis alarms indicate a failure on the device or one of its components. Chassis alarms
are preset and cannot be modified.
Chassis alarms on QFX5100, QFX5110, and QFX5200 devices have two severity levels:
Major (red)—Indicates a critical situation on the device that has resulted from one of
the conditions described in Table 35 on page 147. A red alarm condition requires
immediate action.
Minor (yellow)—Indicates a noncritical condition on the device that, if left unchecked,
might cause an interruption in service or degradation in performance. A yellow alarm
condition requires monitoring or maintenance.
Table 35 on page 147 describes the chassis alarm messages on QFX5100, QFX5110, and
QFX5200 devices.
Table 35: Chassis Alarm Messages
Recommended ActionCLI MessageAlarm TypeComponent
Replace the fan module and report the
failure to customer support.
Fan FailureMajor (red)Fans
Check the system log for one of the
following error messages and report the
message to customer support:
CM ENV Monitor: Get fan speed failed.
fan-number is NOT spinning @ correct
speed, where fan-number can be 1, 2, 3,
4, or 5.
Fan I2C Failure
Remove and check the fan module for
obstructions, and then reinsert the fan
module. If the problem persists, replace
the fan module.
Fan fan-number Not Spinning
Check the system log for the error
message fan-number Absent, where
fan-number can be can be 1, 2, 3, 4, or 5.
Install fan modules in the slots where
they are absent.
Fan/Blower AbsentMinor (yellow)