CHAPTER 16
Removing the Device
Installing and Removing QFX5110 Hardware Components on page 123
Powering Off a QFX5110 on page 124
Removing a QFX5110 from a Rack on page 126
Installing and Removing QFX5110 Hardware Components
The QFX5110 switch chassis is a rigid sheet-metal structure that houses the hardware
components. The field-replaceable units (FRUs) in QFX5110 switches are:
Power supply
Fan module
SFP+ transceiver
QSFP+ transceiver
QSFP28 transceiver
All of the QFX5110 FRUs are hot-insertable and hot-removable: you can remove and
replace them without powering off the switch or disrupting switch functions.
CAUTION: Replace a failed power supply with a new power supply within 1
minuteof removalto prevent chassis overheating.Replace a failed fanmodule
with a new fan within 1 minute of removal to prevent chassis overheating.
To install a power supply in a QFX5110, follow the instructions in “Installing a Power
Supply in a QFX5110” on page 109. To remove a power supply from a QFX5110, follow the
instructions in “Removing a Power Supply from a QFX5110” on page 111.
To install a fan module in a QFX5110, follow the instructions in “Installing a Fan Module
in a QFX5110” on page 105. To remove a fanmodule from a QFX5110, follow the instructions
in “Removing a Fan Module from a QFX5110” on page 106.
To install an SFP+, QSFP+, or QSF28 transceiver in a QFX5110, follow the instructions in
Installing a Transceiver. To remove an SFP+ , QSFP+, or QSFP28 transceiver from a
QFX5110, follow the instructions in “Removing a Transceiver” on page 116.
123Copyright © 2017, Juniper Networks, Inc.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper QFX5110 and is the answer not in the manual?

Juniper QFX5110 Specifications

General IconGeneral
ModelQFX5110
Power SupplyDual, hot-swappable
Rack Units1U
Operating Relative Humidity5% to 90% non-condensing
Input Voltage100-240 VAC
Operating SystemJunos OS
Layer SupportLayer 2 and Layer 3
Virtual Chassis SupportYes
Ports48 x 10GbE SFP+
Jumbo Frames9216 bytes
Operating Temperature32°F to 104°F (0°C to 40°C)
Operating AltitudeUp to 3, 048 m
ManagementCLI
AC Input Frequency50/60 Hz
Storage Temperature-40°C to 70°C
MTBFConsult Juniper documentation for specific values.