12. Temperature sensor offset (t
r0
)
Temperature sensor offset (t
r0
) can be adjusted in ”SETUP loop”. Depending on the meter’s configuration this
function can be disabled and the menu point will in that case display “Off”.
Offset can be adjusted in the interval -0,99…0,99 K. Pressing the secondary key the 0 and the sign start flashing and it
is now possible to toggle between – and +, indicated in the display by the fact that the minus sign flashes and
switches of respectively. Pressing the primary key the meter shifts focus to the first decimal, i.e. it is not possible to
change the value of the first digit as the valid interval is -0,99…0,99 K. Both the first and the second decimal can be
set to a value between 0 and 9. Read more about temperature sensor offset in paragraph 7.3.
Please be aware that the required offset adjustment must be entered, not the error of the temperature sensor set.