All other bits can remain at the factory settings for this example and are explained in the following chapters.
● Block 0 denes the start position → PS.28 = 0
● block 0 → PS.23: Index / selection = 0
Position = 0 → PS.24: Index / position = 0
Permitted max. speed = 1500 rpm → PS.25 = 1500 rpm
next positioning step dened in block 1 → PS.26 = 1
no automatic starting of the drilling process, but waiting for "start position" command, i.e. "continuati-
on of the prole processing“ = 0: no and „position setting“ = 0: absolute
→ PS.27 = 0: no + absolute
● block 1 → PS.23: Index / selection = 1
Position = material surface → PS.24: Index / position = 95000
Advance to material surface → PS.25 = 1500 rpm
next positioning step dened in block 2 → PS.26 = 2
automatic continuation of the drilling process, i.e., "continuation of the prole processing" = 1:yes and
"Position setting" = 0:absolute → PS.27 = 1: yes + absolute
● block 2 → PS.23: Index / selection = 2
Position = end of penetration → PS.24: Index / position = 100.000
max. speed penetration → PS.25 = 250 rpm
next positioning step dened in block 3 → PS.26 = 3
automatic continuation of the drilling process → PS.27 = 1: yes + absolute
● block 3 → PS.23: Index / selection = 3
Position = end of drilling → PS.24: Index / position = 150.000
max. speed drilling → PS.25 = 500 rpm
next positioning step dened in block 4 → PS.26 = 4
automatic continuation of the drilling process → PS.27 = 1: yes + absolute
● block 4 → PS.23: Index / selection = 4
Position = material surface → PS.24: Index / position = 95.000
max. speed retraction → PS.25 = 700 rpm
Retraction to starting position dened in block 0 → PS.26 = 0
automatic retraction to starting position → PS.27 = 1: yes + absolute
Posi- and synchronous operating
© KEB, 2012-10 COMBIVERT F5-A, -E, -H Page 7.12 - 43
7