Keysight N9912-90001 User’s Guide 9-11
Interference Analyzer (SA Mode) – Option 236
Spectrogram and Waterfall Displays
— Playback State/Tag Allows you to continue playback from a state
tag, or scroll through the state tags. Enter a value between 1 and the
total number of state tags using the numeric keypad, arrows, or
the rotary knob. Learn more in “About State and User Tags” on
page 9-9.
— Playback Trace
Activated automatically when Paused. Allows you to
continue playback from a specific trace, or scroll through traces
manually. Enter a value between 1 and the total number of traces
using the numeric keypad, arrows, or the rotary knob.
— Stop
Immediately stops playback. Then choose from the following:
— Play
Start playback from trace 1.
— Record
Resume recording from the last recorded trace.
— Record Playback Setup
Return to the setup menu to change
Configuration settings or Close the session.
Recording Configuration
To change Recording Configuration settings:
—Press Trace 6
.
—Then Record Playback
.
—Then Record Playback Setup
.
—Then New Session
or Recall an existing session.
—Then Recording Configuration
.
Then choose from the following:
— Record Time
Sets the amount of time to record traces. Default is MAX,
which is to record indefinitely. Enter a value between 1s and 1 Ms (million)
seconds using the numeric keypad, arrows, or the rotary knob. When
set, a timer appears during recording in the lower-left corner which counts
DOWN from the specified time.
— Record Source
Sets where, in the FieldFox data flow, data is recorded.
Learn more in “Record Source” on page 9-13. Choose from the following:
— RawMeas
Records raw measurement data.
— Trace 1,2,3,4
Records data from the corresponding trace in its
current state.