18 Close the landing doors. Check that the landing door is
mechanically locked.
19 Go to the maintenance access panel
(MAP). Open the MAP
.
20 Reset the Shaft Access Monitor (SAM),
if applicab
le.
Related information: APPENDIX B.
Resetting the safety devices.
21 Reset the pit safety device.
22 Try to drive on normal drive. The elevator car must not
move
.
23 Make notes of the test. After completing all tests, record the test
date
and all results in the elevator’s log
book at once.
24 Close and lock the maintenance access
panel.
25 Go
to the pit.
See steps 5 – 12.
Step Action Illustration/Note